عنوان المقالة: Testing of a submersible motor-pump group
طيار مهندس/ محمد الشعلان | Capt. Mehmed asch-Schaalan | 5340
نوع النشر
معيار/مقياس
المؤلفون بالعربي
طيار مهندس/ محمد الشعلان، نويليا نونيز، ساشين ناجاراجا، فرانسيسكو لوبيز
المؤلفون بالإنجليزي
Mehmed asch-Schaalan, Noelia Nunez, Sachin Nagaraja, Francisco Lopez
الملخص الانجليزي
During the this laboratory session, a motor-pump submerged under water was the subject of the experiment. One of its purpose is to drain water from a lower reservoir to a higher reservoir. The motor of the pump is a sealed squirrel cage. This type of motors are chosen due to their robustness and ability to function under water. The pump has five identical stages with components such as centrifugal rotor, a vanned diffuser and outlet channels to avoid vortex. Vortex or cavitation can have severe effects on the performance of the pump, creating bubbles that can reduce the section used by the fluid, even causing fatal damage on the pump. The bears inside the pump that holds different components together, avoiding direct physical contact and friction.
تاريخ النشر
04/06/2021
رقم المجلد
رقم العدد
رابط DOI
10.13140/RG.2.2.33723.75042
رابط الملف
تحميل (0 مرات التحميل)
رابط خارجي
https://www.researchgate.net/publication/352786264_Testing_of_a_submersible_motor-pump_group
الكلمات المفتاحية
Motor, pump, testing, energy, efficiency, power, speed, laboratory, lab
رجوع