عنوان المقالة: EVALUATION OF RADIATION DOSE FOR SELECTED SCHOOLS IN THE NORTH SECTION AT AN-NAJAF GOVERNORATE, IRAQ
لبنى عبد الرسول مهدي | Lubna abdulrasool Mehdi | 3033
- نوع النشر
- مجلة علمية
- المؤلفون بالعربي
- المؤلفون بالإنجليزي
- LUBNA A. ALASADI, AND MOHAMMED HAIDER AL-TAWEEL
- الملخص الانجليزي
- In the present study, a gamma background radiation dose at indoor and outdoor for selected schools was determined in the north section at An-NAJAF governorate, Iraq. Measurements were performed using a portable dosimeter survey “Inspector Alert model RAP RS1, S.E. international, Inc, USA”. Average of indoor and outdoor mean rate dose was ranged from (307.543 - 66.744nGy/ h) respectively, Amount of minimum and maximum mean dose were ranged from (269.808 ± 63.331 and 55.188± 15.832 nGy/h) and (343.398± 40.054 and 73.584±10.013 nGy/h) successively. Annual Effective Dose indoor and outdoor were enumerated between (0.33 and 0.27 mSv/y), (0.42 and 0.36 mSv/y) respectively, while the average of Annual Effective Dose ranged between (0.376 – 0.34). So, according to the results of the area under study, this would not pose a significant risk to human beingswhich is recommended by UNSCEAR (2000).
- تاريخ النشر
- 01/09/2019
- الناشر
- EM International , Pollution Resaerch
- رقم المجلد
- رقم العدد
- 28
- ISSN/ISBN
- ISSN 0257–8050
- الصفحات
- 515-518
- رابط الملف
- تحميل (94 مرات التحميل)
- الكلمات المفتاحية
- KEY WORDS : Annual Effective Dose, portable dosimeter, Mean rate dose, An-Najaf governorate, Iraq