عنوان المقالة: Survey of Absorbed Dose Rates in air of Buildings Agriculture and Sciences in University of Kufa at Al-Najaf Governorate, Iraq
لبنى عبد الرسول مهدي | Lubna abdulrasool Mehdi | 2617
نوع النشر
مجلة علمية
المؤلفون بالعربي
المؤلفون بالإنجليزي
Allawi Hamed Alasadi, Azhar S. Alaboodi, Lubna A. Alasadi and Ali Abid Abojassim
الملخص الانجليزي
Indoor and Outdoor absorbed dose rates were measured in select region of AL-Qizweenia Najaf in Iraq. Measurements were perform using a Portable dosimeter Survey (Inspector Alert Model RAP RS1,S.E.international,Inc, USA). The results show that the values of absorbed dose indoor and outdoor were ranged from 696 to 1592.1 nGy/hr and from 565.5 to 1070.1 nGy/hr respectively. The average absorbed dose indoor and outdoor rates were 950.91 nGy/hr and 810.84 nGy/hr of every buildings and laboratories. According to occupancy factor of 0.8 and 0.2, the corresponding average annual effective dose indoor and outdoor rates were calculated to be, 4.66 mSv/yr and 0.99 mSv/yr, successively. The mean annual effective dose outdoor rate is found to be higher than 1mSv/yr which is the recommended dose limit for the public.
تاريخ النشر
01/12/2016
الناشر
Journal of Chemical and Pharmaceutical Research
رقم المجلد
8
رقم العدد
4
ISSN/ISBN
ISSN : 0975-7384
الصفحات
1388-1392
رابط الملف
تحميل (94 مرات التحميل)
الكلمات المفتاحية
Keyword: Absorbed Dose, Dosimeter, Annual effective dose and University of Kufa
رجوع