عنوان المقالة: Survey of Absorbed Dose Rates in air of Buildings Agriculture and Sciences in University of Kufa at Al-Najaf Governorate, Iraq
لبنى عبد الرسول مهدي | Lubna abdulrasool Mehdi | 3029
- نوع النشر
- مجلة علمية
- المؤلفون بالعربي
- المؤلفون بالإنجليزي
- Allawi Hamed Alasadi, Azhar S. Alaboodi, Lubna A. Alasadi and Ali Abid Abojassim
- الملخص الانجليزي
- Indoor and Outdoor absorbed dose rates were measured in select region of AL-Qizweenia Najaf in Iraq. Measurements were perform using a Portable dosimeter Survey (Inspector Alert Model RAP RS1,S.E.international,Inc, USA). The results show that the values of absorbed dose indoor and outdoor were ranged from 696 to 1592.1 nGy/hr and from 565.5 to 1070.1 nGy/hr respectively. The average absorbed dose indoor and outdoor rates were 950.91 nGy/hr and 810.84 nGy/hr of every buildings and laboratories. According to occupancy factor of 0.8 and 0.2, the corresponding average annual effective dose indoor and outdoor rates were calculated to be, 4.66 mSv/yr and 0.99 mSv/yr, successively. The mean annual effective dose outdoor rate is found to be higher than 1mSv/yr which is the recommended dose limit for the public.
- تاريخ النشر
- 01/12/2016
- الناشر
- Journal of Chemical and Pharmaceutical Research
- رقم المجلد
- 8
- رقم العدد
- 4
- ISSN/ISBN
- ISSN : 0975-7384
- الصفحات
- 1388-1392
- رابط الملف
- تحميل (94 مرات التحميل)
- الكلمات المفتاحية
- Keyword: Absorbed Dose, Dosimeter, Annual effective dose and University of Kufa