عنوان المقالة:تطوير الطريقة والتحقق من صحتها للتقدير المتزامن لأتورفاستاتين وإيزيتيميب في شكل جرعات صيدلانية بواسطة HPLC Method Development and Validation for Simultaneous Estimation of Atorvastatin and Ezetimibe in Pharmaceutical Dosage Form by HPLC
سعيد مزعل موازي | SAEID MEZAIL MAWAZI | 6078
نوع النشر
مجلة علمية
المؤلفون بالعربي
سعيد مزعل موازي و سرينيفاس ريدي
المؤلفون بالإنجليزي
Saeid Mezail Mawazi & GNVCS Reddy
الملخص العربي
A new HPLC method was developed and validated for the determination of Atorvastatin and Ezetimibe in tablet dosage form. The chromatographic separation was achieved on a Inspire C18(4.6 x 250mm, 5m) with a mobile phase combination of phosphate buffer, methanol and Acetonitrile (40:10:50) at a flow rate of 1.2 ml/min, and the detection was carried out by using UV detector at 233 nm. The total run time was 8minutes.The retention time of phosphate buffer, methanol and Acetonitrile were found to be 2.237 min. and 3.164 min. respectively. The performance of the method was validated according to the present ICH guidelines. - See more at: http://www.wjpsonline.org/view_issue.php?title=Method-Development-and-Validation-for-Simultaneous-Estimation-of-Atorvastatin-and-Ezetimibe-in-Pharmaceutical-Dosage-Form-by-HPLC#sthash.XjmeS9TO.dpuf
تاريخ النشر
08/01/2014
الناشر
ًWorld Journal of Pharmaceutical science
رقم المجلد
2
رقم العدد
8
الصفحات
866-870
رابط الملف
تحميل (193 مرات التحميل)
رابط خارجي
http://www.wjpsonline.org/view_issue.php?title=Method-Development-and-Validation-for-Simultaneous-Es
الكلمات المفتاحية
علاج الكوليستيرول , الكوليستيرول , علاج الدهون الثلاثية , اتروفوستاتين , ايزتيمايب , cholesterol tre
رجوع